Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 82-93, 2003.
Article in Korean | WPRIM | ID: wpr-200731

ABSTRACT

PURPOSE: To reduce the irradiation dose to the lungs and heart in the case of chest wall irradiation using an oppositional electron beam, we used an individualized custom bolus, which was precisely designed to compensate for the differences in chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probabilities (NTCPs) and dose statistics both with and without boluses. MATERIALS AND METHODS: Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 cm2 intervals on the planning CT images. A second planning CT was obtained overlying the individualized custom bolus for each patient's chest wall. 3-D treatment planning was performed using ADAC-Pinnacle3 for all patients with and without bolus. NTCPs based on "the Lyman-Kutcher" model were analyzed and the mean, maximum, minimum doses, V50 and V95 for the heart and lungs were computed. RESULTS: The average NTCPs in the ipsilateral lung showed a statistically significant reduction (p<0.01), from 80.2+/-3.43% to 47.7+/-4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral lung was also significantly reduced by about 430 cGy, from 2757 cGy to 2,327 cGy (p<0.01). The V50 and V95 in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V50 and V95 in the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP in the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively. CONCLUSION: The use of an individualized custom bolus in the radiotherapy of postmastectomy chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.


Subject(s)
Humans , Breast Neoplasms , Heart , Lung , Lymph Nodes , Prescriptions , Radiation Pneumonitis , Radiotherapy , Thoracic Wall
2.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 1-16, 2002.
Article in Korean | WPRIM | ID: wpr-43230

ABSTRACT

PURPOSE: Three dimensional conformal radiotherapy planning is being used widely for the treatment of patients with brain tumor. However, it takes much time to develop an optimal treatment plan, therefore, it is difficult to apply this technique to all patients. To increase the efficiency of this technique, we need to develop standard radiotherapy plans for each site of the brain. Therefore we developed several 3 dimensional conformal radiotherapy plans (3D plans) for tumors at each site of brain, compared them with each other, and with 2 dimensional radiotherapy plans. Finally model plans for each site of the brain were decided. MATERIALS AND METHODS: Imaginary tumors, with sizes commonly observed in the clinic, were designed for each site of the brain and drawn on CT images. The planning target volumes (PTVs) were as follows; temporal tumor-5.7x8.2x7.6 cm, suprasellar tumor-3x4x4.1 cm, thalamic tumor-3.1x5.9x3.7 cm, frontoparietal tumor-5.5x7x5.5 cm, and occipitoparietal tumor-5x5.5x5 cm. Plans using parallel opposed 2 portals and/or 3 portals including fronto-vertex and 2 lateral fields were developed manually as the conventional 2D plans, and 3D noncoplanar conformal plans were developed using beam's eye view and the automatic block drawing tool. Total tumor dose was 54 Gy for a suprasellar tumor, 59.4 Gy and 72 Gy for the other tumors. All dose plans (including 2D plans) were calculated using 3D plan software. Developed plans were compared with each other using dose-volume histograms (DVH), normal tissue complication probabilities (NTCP) and variable dose statistic values (minimum, maximum and mean dose, D5, V83, V85 and V95). Finally a best radiotherapy plan for each site of brain was selected. RESULTS: 1) Temporal tumor; NTCPs and DVHs of the normal tissue of all 3D plans were superior to 2D plans and this trend was more definite when total dose was escalated to 72 Gy (NTCPs of normal brain 2D plans : 27%, 8% 3D plans : 1%, 1%). Various dose statistic values did not show any consistent trend. A 3D plan using 3 noncoplanar portals was selected as a model radiotherapy plan. 2) Suprasellar tumor; NTCPs of all 3D plans and 2D plans did not show significant difference because the total dose of this tumor was only 54 Gy. DVHs of normal brain and brainstem were significantly different for different plans. D5, V85, V95 and mean values showed some consistent trend that was compatible with DVH. All 3D plans were superior to 2D plans even when 3 portals (fronto-vertex and 2 lateral fields) were used for 2D plans. A 3D plan using 7 portals was worse than plans using fewer portals. A 3D plan using 5 noncoplanar portals was selected as a model plan. 3) Thalamic tumor; NTCPs of all 3D plans were lower than the 2D plans when the total dose was elevated to 72 Gy. DVHs of normal tissues showed similar results. V83, V85, V95 showed some consistent differences between plans but not between 3D plans. 3D plans using 5 noncoplanar portals were selected as a model plan. 4) Parietal (fronto- and occipito-) tumors; all NTCPs of the normal brain in 3D plans were lower than in 2D plans. DVH also showed the same results. V83, V85, V95 showed consistent trends with NTCP and DVH. 3D plans using 5 portals for frontoparietal tumor and 6 portals for occipitoparietal tumor were selected as model plans. CONCLUSION: NTCP and DVH showed reasonable differences between plans and were thought to be useful for comparing plans. All 3D plans were superior to 2D plans. Best 3D plans were selected for tumors in each site of brain using NTCP, DVH and finally by the planner's decision.


Subject(s)
Humans , Brain Neoplasms , Brain Stem , Brain , Rabeprazole , Radiotherapy , Radiotherapy, Conformal
SELECTION OF CITATIONS
SEARCH DETAIL